Low coolant alarm for Falcon EF & ELMany vehicles have some sort of coolant high-temperature warning gauge or lamp. However, a water level switch is the best detector of sudden coolant loss, if catastrophic engine damage is to be avoided. Ford Falcon GLi EF and EL models have provision for installation of a low-coolant sensor in the surge tank. The Fairmont and Fairlane, which have the sensor as standard, operate an instrument panel warning light via the instrumentation computer. However, to retrofit this to other models, a simple electronic interface is required. The proprietary Ford magnetic level switch (Fig.2) measures 180Ω at correct (high) water level and 1380Ω at low water. These resistances are too high to operate typical automobile 85Ω relay coils, which draw about 150mA at 13.8V DC. To solve this problem, a simple transistor circuit can be used to buffer the output from the level switch, as shown in Fig.1. D1 ensures that the circuit does not prematurely trigger with high battery voltages, while LED1 provides low water indication. The latter should be sufficiently bright under most daylight conditions. Q1 & Q2 can be any general-purpose small-signal switching transistors. Modern vehicles perform a self-check of the warning lights when the ignition is first switched on. Ideally, a fail-safe test of the water level circuit should also occur but in this case, the magnetic switch is always closed. That’s the reason for pushbutton "test" switch S2 – it turns Q1, Q2 and LED 1 on when pressed to show that the circuit is working. It’s not fail-safe but satisfactory if you remember to occasionally press the switch. All components except the LED and S2 can be built on a tag strip, which can then be mounted behind the clock panel. The panel facia is drilled to take a suitable rubber grommet or bezel to accommodate the LED. The circuit operates from 10-15V, which is taken from the fused side of the ignition circuit. The Ford sensor kit includes an "O" ring seal and locking nut. Before removing the proprietary electrical connector, thoroughly test the sensor and circuit by moving the float up and down. This is important, as Ford will not refund a damaged or modified unit! Obviously, the surge tank has to be drained below the threaded mounting point and a hole cut through this existing mount with a hole saw. Take care not to damage the threads. Retrieve all swarf to prevent pipe blockages. Refill with correct coolant and check for leaks under normal engine working conditions. Warning: header and surge tanks operate at pressures in excess of 100kpa (15psi) and up to 125°C using 33% Glycol coolant! Robert Gott, Toowoomba, Qld. ($30)
Simpler PC power-upHere is an even simpler alternative to the auto power-up of ATX
PCs mentioned in the June 2004 issue; it requires no parts at all! To prevent the power supply from entering standby mode, the "PS_ON" signal can be strapped permanently low. This can be achieved by cutting the track leading to pin 14 of the connector on the motherboard. A wire link can then be soldered between pin 14 and pin 15 ("COM") of the connector. If you don’t want to modify your motherboard, you may be able to remove the respective pin from the rear of the power supply connector housing and splice it into one of the "COM" return wires. Obviously, this will disable standby functionality completely, including front-panel power button control. This is great for auto power-up of servers on resumption of power after a UPS low-battery shutdown. I have my file server in the roof at home and this saves getting the ladder out after the all too frequent power failures. Before getting the tools out, it pays to check that your motherboard does not already have provision for automatic power-up when mains power is applied. This might be in the form of a jumper or settings in the BIOS, as detailed in "Mailbag" on page 4 of the September 2004 issue. Tarek Heiland,
Water pump monitorThis circuit is designed to stop a fresh water pump from running too long. When you live on the land, your water supply is stored in tanks and you tend to be more vigilant about water use. If, for example, a pipe ruptures or a tap is left open, loss of pressure in the line will cause the pump to start. If the owner does not know this or is away, then the pump could empty a full tank within a short time. The project was conceived when a water pipe burst while I was away for the weekend. Luckily, a neighbour noticed the water spout and shut the pump off. If the tank had emptied that would have been bad enough but the cost of a burnt-out pump would have been much worse. Another use is as a timer for watering the garden. Pick a time and turn on the tap. This unit will shut off the pump and sound an alarm at the end of the selected time. Perhaps you have teenagers that like to take long showers. Set the time to 10 minutes and watch them complain! Five different times are available and these can be altered to suit your needs by editing the microcontroller program. To reset the pump after a time out, simply press the reset button for two seconds. The circuit works by detecting the vibrations from the pump while it is running. When the pump starts, a timer is started and after the set time has elapsed the pump will be shut off and an alarm sounded. If the pump you have is quite powerful, pressure in the line can build up high enough to stop the pump. If a tap is still open, the pump will start again when the pressure drops. The software takes all this into consideration and is not fooled by the pump switching on and off. The pump must be off for more than 20 seconds for the program to reset the timer and think that the tap has been closed. A PICAXE-08 microcontroller runs the whole show. It knows the pump is running because a piezo sensor is physically mounted on the pump. Motor vibrations excite the piezo sensor, generating a small AC voltage across its terminals. This signal is amplified by op amp IC2a, which is set for a gain of about 85. From here, the signal is rectified by a diode pump circuit and then compared with the voltage on the wiper of VR1 by op amp IC2b. When the voltage on pin 5 exceeds that on pin 6, the output of the op amp swings high, turning on Q3. This turns on the LED and pulls pin 3 of the micro (IC1) to a logic low level via D4. Next, the micro reads the voltage on pin 6 as selected by S1. As this pin is an ADC (analog-to-digital converter) input, the voltage read will vary according to the position of the switch. The result is used by the program to select one of five times from a look-up table stored in memory. The pump "run" timer now starts and if the signal on pin 3 remains low (pump on) for longer than the selected time period, the micro drives pin 7 high to switch on Q2, sounding the alarm. More importantly, it also drives pin 5 high, switching on Q1 and energising the relay, which in turn opens the normally-closed contacts to disconnect the pump motor. To reset the pump, just press the reset button (S2). The pump will now start again because there will be no pressure in the line. Once pressure has built up again the pump will stop, assuming you have turned off the offending tap or fixed the fault with the lines. The five selectable times are determined by the number stored in the "time" variable. Each unit equals one second. For example, to set a time of 30 minutes, the number 1800 would be used. As it stands, the program has been set for 90, 45, 30, 20 and 15 minutes. When mounting the piezo sensor, make sure that it is physically touching the pump. Most pumps have removable end plates. The disc can be inserted between the end plate and the pump body. Any single-plate piezo transducer can be used for the job. Many piezo transducers come with a plastic surround. Remove the disc by prising it out of the surround before mounting. Oatley Electronics sells discs that are ideal for this application. Jeff Monegal,
Reducing the effective mains voltageWould you like to use a particular power transformer in an amplifier or some other project you’re building but its secondary voltage is just a little too high? Or perhaps you have an imported piece of equipment with a power transformer rated for a mains voltage of 220V, so it gets too hot and bothered running from 240V? It’s easy to solve these and similar problems by using a standard off-the-shelf low voltage transformer as a DIY autotransformer, to reduce the effective mains voltage fed to your equipment. The idea is to connect some or all of the secondary winding of the extra transformer in series with the mains voltage fed to your equipment, with its polarity chosen so that its voltage subtracts from the 240V input (see circuit A). Here a standard transformer with a 12V-0-12V secondary winding is connected with the full secondary in series with the active output lead, so the effective output voltage becomes 240V - 24V, or 216V. This exact arrangement would be fine for any application where you need to reduce the mains voltage for equipment by about 10%, to make its power transformer run cooler or to bring its secondary voltage down so your power supply electros can be run within their ratings. Of course, if you don’t need to reduce the mains voltage by a full 10%, you could use only half the secondary winding connected in series with the active output lead. This will give an output voltage of 240V - 12V, or 228V (a reduction of 5%). Or you could use a transformer with a multi-tapped secondary voltage, which would allow you to reduce the output voltage in steps of 1.5V or 3V. When you’re choosing the transformer for this kind of use, make sure that its secondary winding is rated to handle the full-load primary current of the main power transformer in the equipment it’s to be used with. So if your amplifier has a 300VA power transformer, for example, its full-load primary current will be around 1.25A (300/240V). In this case, you’d pick a mains-reduction transformer with a secondary winding rated to handle 1.5A or 2A and with a voltage equal (or close) to the mains voltage reduction you want. Can you use the same kind of transformer to step up the effective mains voltage by 10% or so? Yes, simply by connecting its secondary winding (or a part of it) in series with the active mains lead with its polarity reversed, so the secondary voltage adds to the output instead of subtracting. This is illustrated in circuit B, where the same transformer is connected with half its secondary in series, to add 12V to the mains input and deliver an output of 252V. Note that because both of these circuit configurations use the additional transformer as an autotransformer, they do not provide any isolation. For safety reasons, fit the transformer in a sturdy metal box, and connect both the box and the transformer frame to mains earth. SILICON CHIP.
Share this Article:
|
||||||||||||||||||||||||||||||
|