Last month, we gave
the circuit details for
our new Digital
Instrument Display
and showed you how
to build it. This
month, we describe
how to connect
different sensors to
the unit and give the
calibration details.
Digital Instrument
Display For Cars
Pt.2: By JOHN CLARKE
F
IG.4 SHOWS THE TYPICAL sensor
and meter connections that are
found a vehicle. Generally, the sensor
is grounded and the existing analog
meter connects in series with this to
a regulated supply. The other possible
configuration is when the meter itself
is grounded and the sensor connects
to the regulated supply instead.
In either case, you can connect to
the junction of the sensor and the
meter (marked with an ‘x’) to obtain a
signal to drive the Digital Instrument
Display.
Alternatively, the sensor can be
rewired as shown in Fig.5, using a
fixed resistor (R1) to replace the meter.
Note that R1 can be installed on the
microcontroller board.
It is important to note that the Digital
Instrument Display is designed to accept a signal voltage at its input which
is within a certain range. So you will
78 Silicon Chip
need to make some measurements to
check whether the voltage range from
the sensor is suitable. If the signal
voltage is outside the limits, it can be
tailored using several adjustments at
the input to make it suit.
The voltage limits for the Digital
Instrument Displays input are as
follows:
(1) with R3 out of circuit, the unit can
be used with voltages ranging from
0.5-4.5V.
(2) with R3 in circuit and VR1 adjusted
so that the unit can read down to 0V,
the Digital Instrument display can
measure up to 2.7V when VR2 is fully clockwise (250kΩ) and up to 3.4V
when VR2 is fully anticlockwise (0Ω).
Attenuating the input voltage
The value of R1 (see Fig.5) needs to
be selected so that the voltage across
the sensor remains within the allow-
able range. Typically, R1 would be a
330Ω (0.25W) resistor and the circuit
would be configured with VR2 fully
anticlockwise, R3 in circuit and R2
omitted.
However, if the sensor voltage goes
above 2.7V, you can adjust VR2 so that
signal voltages up to 3.4V can be monitored. Higher input voltages will need
to be attenuated by fitting resistor R2.
R2 can be calculated if the maximum input voltage (Vin max.) to be
applied to the input is known. The
circuit for the attenuator is shown in
Fig.6. If VR2 is set at its mid-position,
the value for R2 = 30kΩ/(Vin max. - 3).
For example if the maximum input
voltage is 8V, R2 will be 30kΩ/5 or
6kΩ. A 5.6kΩ resistor would be suitable. VR2 is then used to adjust the
range of the signal voltage that can be
applied to the circuit.
Trimpot VR1 will require adjustwww.siliconchip.com.au
Fig.4: typical sensor and meter connections as found
in a vehicle.
Fig.6: resistor R2 is necessary
only if the signal voltage (ie,
from the sensor) goes above
3.4V. Its value is calculated as
described in the text.
ment if resistor R3 is installed. Also,
this adjustment will need to be redone
if VR2 is altered. In practice, VR1 is
adjusted by connecting the input to the
Digital Instrument Display to 0V and
selecting the input mode by pressing
the Mode switch four times (ie, four
times from the normal display position
mode).
Note, however, that trimpot VR1 is
NOT adjusted for a display reading
of 0 (if it does show 0, then trimpot
VR1 is too far clockwise). Instead, you
have to adjust VR1 so that the display
shows a reading between about 97
and 110.
Fig.7 shows how to use the Digital
Instrument Display with an LM335
temperature sensor. Typically, the output from the sensor varies by 10mV/°C,
with the output at 2.73V at 0°C.
Calibration
We have already described how
the calibration modes are accessed by
pressing the Mode switch. As previwww.siliconchip.com.au
Fig.7: how to use the Digital
Instrument Display with an LM335
temperature sensor (see text).
ously stated, calibration is performed
at two different points and the instru
ment then calculates the readings for
the remaining input voltages.
Before starting calibration, you must
first decide on the display readings
that are required at these two points.
For example, for a temperature gauge,
you might select 0°C and 100°C for the
two calibration points. Alternatively,
for a fuel gauge, you could calibrate the
unit at 10 litres and 50 litres.
These values are then entered as the
Fig.5: R1 needs to be selected so that
the voltage across the sensor remains
within the allowable range. Typically,
R1 would be a 330Ω (0.25W) resistor
and the circuit would be configured
with VR2 fully anticlockwise, R3 in
circuit and R2 omitted.
Fig.8: a 1kΩ trimpot connected
between the +5V rail and
ground can be used to set input
voltages to calibrate the unit.
first and second calibration numbers.
Note that the first calibration number
must correspond to the lower of the
two voltages applied to the instrument
during calibration. So, taking our first
example, if the sensor gives a lower
signal voltage at 0°C than at 100°C,
then the 0 is entered into the first calibration position and the 100 is entered
into the second calibration position.
Alternatively, if the sensor gives a
lower voltage at 100°C compared to
that at 0°C, the 100 must be entered
Installing The Unit In A Vehicle
Use automotive cable and connectors when installing the Digital Instrument
Display into a vehicle. The +12V supply connection is derived via the ignition
switch and a suitable connection point will usually be found inside the fuse
box. Be sure to choose the fused side of the supply rail, so that the existing
fuse is in series with the unit.
The ground connection can be made by connecting a lead to the chassis
via an eyelet and self-tapping screw.
Similarly, use automotive cable to connect to the chosen vehicle sensor
or sender unit.
September 2003 79
Fig.9: here’s how to use the
alarm output: (A) low current
piezo siren; (B) driving an external 5V relay; and (C) driving
an external 12V relay. Note that
in (C), the alarm sense must be
reversed (during calibration) so
that a high alarm output drives
the relay (see text).
into the first calibration position
and the 0 into the second calibration
position.
The same applies for a fuel gauge or
oil pressure gauge – ie, use the figure
that gives the lowest signal voltage in
the first calibration position and the
figure that gives the highest signal
voltage in the second position.
Calibration signals
In order to calibrate the unit, you
need to feed in a signal voltage that’s
the same as that provided by the sensor
at each calibration point. To do this,
you can either use the actual sensor
itself or you can use a 1kΩ trimpot
which is connected to the input as
shown in Fig.8.
As mentioned before, the two calibration positions are selected using
the Mode switch. If the first calibration
position is to be calibrated, apply the
80 Silicon Chip
calibration voltage, then select this
position by pressing the Mode switch
once after the “normal” mode.
Now wait for several seconds for the
voltage at the input to be measured by
the Digital Instrument Display. Now
press the Up switch and then the
Down switch, so that the value is the
same as before. This needs to be done
as calibration can only take place
when the calibration value is changed.
Simply selecting the calibration value
with the Mode switch will not calibrate the Digital Instrument Display.
The second calibration voltage is
then applied and the Mode switch
pressed again to show the second calibration number. Wait a few seconds,
then press the Up and Down switches
to calibrate this value.
Note that there is no need to feed
in both calibration values at the same
time – calibration can be done for
either the first or second position at
any time (even weeks apart if that’s
more convenient).
In fact, if you are calibrating the unit
for a fuel sensor, the best approach is
to calibrate it for one value when the
tank is full and then wait until the tank
is almost empty to feed in the other
calibration number.
Alternatively, you can do this the
other way around – ie, feed in one
calibration number when the tank
is empty, then fill up and feed in the
other calibration number.
Note that the “normal” readings will
not be correct until both calibration
values have been entered.
Checking signal levels
It’s important to check that the voltages applied to the Digital Instrument
Display are not beyond its range. This
can be done by pressing the Mode
switch four times from its normal
display mode to select the input reading mode. The display should show
a value between about 100 and 940.
Values much below 100 will go to “0”
and values much above 940 will show
“FUL” on the display.
A “0” or “FUL” indicates that the
voltage applied to the Digital Instrument Display is out of range and the
voltage will need to be altered as
previously described using R1, R2,
VR1 and VR2.
Measuring sensor voltages
Calibration of the instrument with a
fuel or oil pressure sensor can initial-
ly be done by measuring the voltage
across the sensor in its standard form
when connected to the original analog
meter. You will need to connect your
multimeter so that the measurement
can be made over the full range of
outputs from the sensor during normal
running of the car. That way, you will
gain a good idea of the voltages that
are produced by the sensor.
During this time, record two voltages that correspond to two particular
markings on the meter. The further
apart the voltages are, the more accurate the calculation for other values
will be.
Be sure to check the voltages obtained during this process against the
allowable limits. You can attenuate
the level using R2 if the voltage range
from the sensor is too great. Similarly,
if the voltage goes below 0.5V, you will
need to install R3 and then adjust VR1
as detailed above.
You can then calibrate the instrument using the voltages found by
measurement and by using a 1kΩ
trimpot connected as shown in Fig.8.
That done, disconnect the car instrument from its sensor and measure the
instrument’s resistance to determine
the value of R1.
It’s then just a matter of installing
R1 on the microcontroller board, as
shown in Fig.5.
Temp. sensor calibration
Calibrating the unit for use with
a temperature sensor can be done at
0°C and at 100°C The 0°C calibration
is done using freshwater ice which is
stirred in a small amount of cold fresh
water. Stir the solution with the sensor
immersed in it to ensure it reaches the
0°C of the water/ice solution before
entering “0” for the first calibration
number.
Note that if you connect a multi
meter across the sensor, it will stop
changing value when it reaches 0°C
– ie, it will reach either a minimum
or maximum output.
By contrast, the 100°C calibration
is done by immersing the sensor in
boiling fresh water. Again ensure
that the sensor output has stabilised
in the boiling water by monitoring its
output voltage before entering in the
calibration number.
Just remember that the calibration
number corresponding to the lowest
sensor voltage goes in the first calibration position. So if the sensor voltage
www.siliconchip.com.au
Fig.10: here are the full-size patterns for the two PC
boards, together with the full-size front-panel artwork
which can be used as a drilling template. Check your
PC boards carefully for defects before installing any
parts.
at 0°C is lower than at 100°C, then “0”
goes in the first calibration position
and vice versa.
Once calibrated the instrument will
display values based on a calculation
that assumes a straight line (linear) relationship between the two calibration
points. It will also calculate the values
outside the two calibration points,
again assuming a linear relationship.
For example, when connected to a
temperature sensor, the display will
show temperatures below 0°C when
the sensor is colder than this and also
above 100°C if the sensor is hotter than
this value. In fact, the display can
show values between -99 and 999 but,
in practice, may be restricted to a range
that’s less than this, depending on the
signal voltages applied to the unit and
the voltage excursion of the sensor.
Using the alarm output
The alarm is set to the required value by first pressing the Mode switch
three times from the “normal” mode
position. You then set the value using
the Up and Down switches and select
the sense as described earlier. The
latter determines whether the alarm
activates as it goes above or below the
calibrated value.
www.siliconchip.com.au
The alarm output goes low under
alarm conditions and this lights the
alarm decimal point in DISP3. In addition, a low-current piezo siren could
be connected between the +5V supply
and the alarm output if an audible
alarm is required – see Fig.9(a). The
Jaycar AB-3462 piezo siren would be
suitable, as it draws less than 15mA
when used at 5V.
External relay
Fig.9(b) shows how to connect an
external relay to the alarm output.
You need to build up a small circuit
consisting of a 10kΩ resistor, a BC327
PNP transistor and a diode. The relay
needs to be a 5V or 6V type since it is
powered from a 5V supply.
Alternatively, the circuit shown at
Fig.9(c) can be built. This circuit can
drive a 12V relay but note that the
alarm sense will have to be reversed
(ie, during calibration), so that a high
alarm output drives the relay rather
than the normal low output level. In
addition, you will have to delete the
visual alarm indication, since this will
no longer be valid.
This simply involves removing resistor R6 to disable the decimal point
indication in display DISP3.
SC
KALEX
PCB Makers!
• High Speed PCB Drills • 3M Scotchmark
Laser Labels • PCB Material – Negative
or Positive Acting • Light Boxes – Single
or Double Sided; Large or Small • Etching
Tanks – Bubble • Electronic Components
and Equipment for TAFEs, Colleges and
Schools • Prompt Delivery
We now stock Hawera Carbide Tool Bits
718 High Street Rd, Glen Waverley 3150
Ph (03) 9802 0788 FAX (03) 9802 0700
ALL MAJOR CREDIT CARDS ACCEPTED
September 2003 81
|