This is only a preview of the August 2015 issue of Silicon Chip. You can view 43 of the 112 pages in the full issue, including the advertisments. For full access, purchase the issue for $10.00 or subscribe for access to the latest issues. Items relevant to "Ultra-LD Mk.4 200W RMS Power Amplifier, Pt.1":
Items relevant to "Accurate Voltage/Current/Resistance Reference":
Items relevant to "Build A Driveway Monitor, Pt.2":
Items relevant to "LED Party Strobe Mk2":
Purchase a printed copy of this issue for $10.00. |
By Nicholas Vinen
Using our Voltage/Resistance/
Current Reference for . . .
Checking &
calibrating
multimeters
Do you trust your favourite multimeter? Does it always tell the
truth? Maybe it doesn’t! We tend to assume that the readings
are accurate but are they? They can drift off calibration quite
markedly as the years pass by. So how old is your multimeter and
has it ever been checked? Now you can use our Voltage/Resistance/
Current Reference to check your multimeter and if necessary,
precisely calibrate it on DC voltage, current and resistance.
D
EPENDING ON how much you
paid for you multimeter, it may
have been very accurate when new.
But if it’s a few years old, its readings
might now be far from accurate. How
would you know? You need to check it
regularly against a reference to ensure
it still meets its specifications.
Ideally, you need several references;
at least one voltage reference, one
siliconchip.com.au
resistance reference and one current
reference. Luckily, our Voltage/Resistance/Current Reference described
elsewhere in this issue gives you all
three, without you having to spend
much money.
Of course, professional multimeter
calibration operations need to have
more complex equipment than this;
they will have very accurate refer-
ences that are themselves periodically
checked against even more accurate
devices and which can be adjusted to
give voltages/currents/resistances/etc
that allow each range of a multimeter
to be calibrated accurately. While our
project only supplies a fraction of that,
it’s still a lot better than nothing.
So assuming you’ve built our
Reference module, how do you go
August 2015 45
If you don’t have a service
manual for your multimeter,
you will have to figure out
which pot does what by a
process of trial and error.
about checking and calibrating your
multimeter?
Checking voltage accuracy
First, if you have a very accurate
multimeter that itself has been recently
calibrated in a NATA-approved facility,
you can use it to test your reference
device and write down the measurements. If you don’t have such a meter,
you will simply have to assume that the
Reference is perfectly accurate. If using
our reference device, this is not a bad
assumption – we measured the nominal 2.5V output error (on a 7.5-digit
multimeter) as just -0.0005% (see
photo overleaf)! Similarly, the nominal
1kΩ resistor was just 0.0134% low
(compared to a 0.1% specification).
Now set the multimeter to be calibrated into DC voltage measurement
mode and set the range to the lowest
range that will read the test voltage
(if it’s auto-ranging, it will select this
automatically). Connect the probes
to the OUT+ and OUT– terminals on
the reference, switch it on and check
the reading. If it is as close to the expected value as the meter can read, you
46 Silicon Chip
know it’s properly calibrated. You can
reverse the probes and check that the
negative reading is equally accurate.
You can also check that the reading
is correct on higher settings, although
the number of digits shown will of
course be reduced so this will be a
less accurate test. Still, it’s worth doing. Note that a typical DMM typically
only has a single adjustment for its DC
voltage mode so if it is out in some
ranges and not others, you probably
won’t be able to improve the situation
without actually replacing some of its
on-board multiplier resistors.
For checking lower voltage ranges,
where the output of the reference will
give an over-range error, you could
connect a resistive divider or potentiometer across the reference outputs,
measure the resulting voltage on the
higher range and then check that the
lower range gives a similar reading.
Resistance mode
Checking the resistance reading is
a similar process. Set the DMM on its
lowest mode that can read 1kΩ (this
will usually be the 2kΩ, 4kΩ or 5kΩ
range) and check that the reading is as
close as possible to the actual value.
To check higher ranges, you could
use the same resistor however it’s better to pick a “random” resistor which is
just below the maximum you can read
on the current range, note its value,
then switch to the next higher range
and verify that the reading is very
close. You can then pick a resistor with
10x the value as the last and repeat the
process up through the ranges.
Ranges below 1kΩ can be checked
using the same procedure, ie, pick a
resistor with a value that’s towards
the upper limit of the lower range (eg,
180Ω), read this value on the same
range as you used to check the 1kΩ
calibration resistor, then switch into
the lower range and verify that the
reading is correct. Then using a smaller
value again, proceed down through the
lower ranges.
Of course, the ideal situation would
be to have a precision resistance box
or a series of individual precision
resistors but in practice, this cheaper
method should do the job.
Ammeter checking
Testing an ammeter with the current source on our reference board is
a little more involved because it has a
high output impedance of 1kΩ. That
means that, depending on the multimeter’s range setting, its shunt resistance
(and by implication, burden voltage)
will affect the reading. However,
you can easily compensate for this.
The simplest method is to use a second multimeter to measure the shunt
resistance of the meter being tested.
The current is nominally 2.5mA for
the 2.5V unit (5mA for the 5V unit,
etc) so it should be suitable for testing
both milliamp and microamp ranges (if
present). To measure the shunt resistance, set the DMM on the range being
tested, then connect the second meter
in resistance mode between its current
measurement terminals.
On our example meter, we got a
reading of 101.28Ω on the microamps
range, 2.2Ω on the milliamps range and
0.077Ω on the amps range.
You can then calculate what the
meter should read in each range by
adding the calibration resistor value
to the measured shunt resistor values
and dividing into the reference voltage. In our case, our calibration resistor
measured 999.866Ω (an error of just
-0.013%!) and our reference voltage
siliconchip.com.au
While the nominal accuracy of the
Maxim voltage reference is ±0.04%,
typically it will be much better, as
demonstrated by this readout on the
Keysight 34470A bench multimeter
reviewed in this issue.
2.499987V. Thus the expected readings for this meter are:
(a) 2.499987V ÷ (999.866Ω +
101.28Ω) = 2.270mA in µA mode
(b) 2.499987V ÷ (999.866Ω + 2.2Ω) =
2.4948mA in mA mode
(c) 2.499987V ÷ (999.866Ω + 0.077Ω)
= 2.5mA in A mode
We didn’t calibrate the example
DMM but we did check its readings against these and got 2.270mA,
2.495mA and 2.5mA respectively. So
it seems it doesn’t need any adjustments for now.
Performing calibration
If any of your checks give results
with a noticeable deviation from the
expected values (ie, more than ±1), you
will probably want to trim the meter to
make it more accurate. Unfortunately,
the procedure for doing this will be
different for each meter but there are
some common steps.
First, you need to gain access to the
trimpots on the PCB(s). This usually involves removing the back of the meter.
If it is in a rubber holder, remove that
first, then look for screws on the back.
There are usually 2-4 screws holding
the back on. You may also need to
remove the battery cover first.
Usually, having undone the screws,
the back will pull off quite easily.
Modern DMMs are usually built on a
single board but some may comprise
two PCBs joined with headers or some
other form of connector. Inspect the
board(s) and locate any trimpots. We’ve
seen as few as one and as many as 12!
If you’re lucky, a service manual
will be available on the internet for
the model of multimeter you are calibrating which details the location and
function of each trimpot.
For example, we had a look for the
manual for our venerable Fluke 77
and found it at the Fluke website. It
confirms that the single trimpot is used
to adjust the DC voltage reading. They
suggest using a test voltage of 3V, which
our reference board can provide with
a suitable reference IC, however 2.5V
should work fine too.
There should be a manufacturerprovided service manual available for
just about every modern, brand-name
DMM on the market. If you have a
re-badged DMM, you may have some
luck if you do a web search to find
out the original manufacturer’s model
number for that product, then look up
the service manual for that product.
If you can’t find a manual for your
meter but there’s only a single pot,
chances are that, like the Fluke 77, it
adjusts the reading in the DC voltage
mode. In that case, it’s just a matter of
hooking the reference up and tweaking
it until the reading is correct. It may
or may not also affect the current and
resistance readings.
If there are multiple trimpots though,
it’s unlikely they will be labelled with
anything other than a code. If you can’t
find a service manual for your DMM,
you’ll have to figure out what they do
the hard way.
First, take a photo of the trimpots so
you can see which position each one is
in, in case you can’t easily re-calibrate
it later. Then, switch the meter into
each mode in turn and adjust each
trimpot. You’ll probably have to hook
something up to the input terminals
in each mode to make changes appar-
ent. Once you figure out what a given
trimpot adjusts, write it down and
move onto the next mode.
Hopefully, by the end of this process you have a full list of what each
trimpot does. You’ll also likely have a
meter that’s way out of calibration! So
calibrate the voltage, resistance and
current pots using the previous explanations for how to check the operation
of each mode. All you have to do is
adjust the appropriate trimpot until
each reading is correct (or as close as
you can get it). If there are any pots that
you can’t calibrate, refer to the photo
you took earlier to set them back into
their original positions.
Note that in some cases, the pots
themselves may not be directly accessible without removing the PCB or
unplugging a sub-module, however
you may find that you can adjust them
from the back through holes in the
board. Generally it’s impossible to calibrate a multimeter without being able
to observe the display while making
adjustments so there’s usually a way
to do it with the board still in the case.
By the way, do not be tempted to
use the 230VAC mains or other highvoltage sources to calibrate a DMM.
It isn’t safe to connect a DMM to the
mains with the case open. You could
get a lethal shock if you do.
Digital calibration
Some modern DMMs use digital
calibration. There’s no need to open
the unit up; calibration is performed
by manipulating the buttons on the
front panel. For example, our Agilent
U1252A and U1253B multimeters use
this procedure.
In this case, you’ll need the service
manual for instructions on how to enter
adjustment mode and perform the calibration. It’s usually a similar process
to adjusting trimpots, except that the
up/down adjustments are made using pushbuttons instead. You’ll still
need the reference board to make the
SC
adjustments.
Issues Getting Dog-Eared?
Are your SILICON CHIP copies getting damaged or dog-eared?
Keep them safe, secure and always available with these
handy binders
REAL
VALUE
AT
$16.95
*
PLUS P
&
P
Order now from www.siliconchip.com.au/Shop/4 or call (02) 9939 3295
and quote your credit card number. *See website for overseas prices.
siliconchip.com.au
August 2015 47
|