Active Mains
Soft Starter
Part One by John Clarke
High startup current appliances can be dangerous, damage your work,
cause brownouts or trip out the circuit breaker when power is first applied.
This Soft Starter prevents the high surge current, replacing it with a slow
current build-up and reducing the ‘kick’ you get from many tools.
H
ave you ever used a power tool
that rips out of your hand when
power is first applied? Or do you have
a bank of computers or audio equipment (or similar) that you want to
power up together from a single power
point? When you do so, sometimes the
circuit breaker might trip, forcing you
to go to the switchboard and reset it.
Tools with a motor that are powered
from the mains, such as circular saws,
drop saws, hand grinders and routers can make a sudden movement
Suitable for fixed or
portable power tools
rated up to 750W
➠ Switch on at GPO or
equipment power
switch, including triggers
➠ Relay contacts bypass
soft start circuitry at
completion for minimal
power loss
➠ Six startup rate options
from half a second to 10
seconds
➠ Indicators for power
presence, soft starting and
soft start end
➠
10A continuous rating
➠
Uses trailing edge
phase control
➠
Features
& Specifications
siliconchip.com.au
inrush current can be caused by the
appliance or appliances using a toroidal transformer or a switch-mode supply that rectifies the mains supply into
a large capacitor or capacitor bank. The
capacitance represents a near short circuit when power is first applied, causing a massive surge current.
This new Active Mains Soft Starter
significantly reduces startup current,
solving that problem. It’s designed
for devices that might be restarted
frequently (like power tools), and its
Active Soft Starter
➠
Also suits large
amplifiers, computers
or other equipment
with a high inrush
current
as the torque from the motor startup
rotates the tool. This can cause the tool
to move dangerously. In the case of a
saw, drill or router, it could move the
cutting piece off position and possibly
damage your work.
You might also hear a nasty “splat”
from the switch or plug when the
equipment is powered up, indicating
that it is being worn out by handling the
high inrush current. All of that can be
solved with a soft starter like this one.
As well as large motors, a high
Australia's electronics magazine
February 2023 33
Fig.1: the mains
waveform is a
50Hz sinewave
with a positive
voltage half the
time & a negative
voltage the rest of
the time.
effect will not diminish, nor will it
overheat with multiple restarts if used
with equipment within its ratings.
You can use the Soft Starter with
motorised tools up to 750W and appliances with substantial capacitance.
Two ways to use it
One way to use the Soft Starter is
to have the appliance already plugged
into the Soft Starter and switched on.
You then switch on power at the GPO
(general purpose outlet). That is ideal
if you want to power up several appliances together from one power point.
In this case, the soft start process
begins at power-up (if an appliance is
connected). Once the soft starting is
completed, it supplies the full mains
voltage until it is switched off at the
power point.
The second method of using the Soft
Starter is to have it powered up via
the power point (GPO), then switch
the appliance on and off with its own
switch. This method is ideal when
using power tools.
For both methods, the soft starter
detects when the appliance is switched
on and off by monitoring its load current. Soft starting only begins when
current flow is detected. When the
appliance is switched off, current
flow ceases, and the power to the tool
is also switched off, ready for another
soft start.
750W rating
We tested the Soft Starter with various loads and power tools and found
that it worked well for tools up to
750W. Some parts got uncomfortably
hot when used with tools that draw
more than that. Also, the ratings of
some of the devices used are only
sufficient up to that power level.
This is less of a concern when
switching equipment like computers
and amplifiers, as their inrush current
periods are short. In that case, you
can comfortably connect up to 10A
(2.3kW) of equipment to the output.
For power tools above the 750W
rating, consider building our Refined
Full-Wave Motor Speed Controller
that incorporates soft starting (April
2021; siliconchip.au/Article/14814).
It is rated to handle 10A and therefore should handle any power tool that
plugs into a standard GPO. You could
leave it set to full speed all the time
and just utilise its soft-starting feature.
Presentation
The Active Soft Starter is housed
in a compact plastic case with an IEC
mains input connector at one end and
a GPO for the appliance. There are
three neon indicators on the top. One
shows when input power is applied;
the second shows the slow voltage rise
to the appliance, while the third lights
when the soft start period has ended.
The neons are very sensitive and
light up with a minimal current
applied, so they don’t show the full
extent of the soft starting. However,
they help to show what the device
is doing.
Soft starting methods
The standard method to reduce the
surge current is to add resistance in
series with the mains supply, reducing the maximum current.
We previously published two soft
starters using that method, one in April
2012 (siliconchip.au/Article/705) and
the other in July 2012 (siliconchip.au/
Article/601).
Both utilised negative temperature
coefficient (NTC) thermistors. These
devices act as a resistor that reduces
its resistance as it heats up from the
current flow through it. As it starts
cold, the resistance is high, so the current is restricted. Then as the thermistor heats up, the resistance drops and
allows more current to flow.
In both designs, after some time,
the thermistor is bypassed by a relay
to provide the full mains supply to
the appliance. Bypassing the thermistor after the soft start prevents further
heating of the thermistor, allowing it
to cool down and be ready to provide
another soft start when required.
Still, if the appliance is powered
up repeatedly at close intervals, the
thermistor does not have time to cool
between uses, so its resistance can be
quite low on successive starts. This
means that the soft starting is not as
effective in such cases.
Another consideration is whether
the NTC thermistor can survive longterm use conducting current for an
appliance that draws significant current at switch-on. If power is switched
on at the maximum voltage point in
the mains waveform, the initial current can be extremely high, especially
if the thermistor is still hot. Over time,
that can damage and possibly destroy
the device.
While our new Soft Starter does use
a thermistor, it also includes phase
control that initially applies a small
portion of the mains waveform. The
proportion of the mains waveform
applied to the load increases slowly
until the full mains cycle is applied.
A relay contact then closes to bypass
the soft start circuitry.
In doing so, it causes very little heating in the thermistor, so repeated starts
are not a problem, and the device is
very reliable.
Also, the phase control always starts
at the beginning of the mains cycle,
when the mains voltage is close to
0V. The control scheme used is called
trailing-edge phase control and differs
from the leading-edge phase control
Fig.2: traditional leading-edge phase
control varies the switch-on point
during the mains cycle but always
switches off at the zero crossing. So
the earlier it switches on, the more
power is applied to the load.
…continued opposite
34
Silicon Chip
Australia's electronics magazine
siliconchip.com.au
Warning: Mains Voltage
The entire circuit of the Active
Soft Starter floats at mains
potential and could be lethal
should you make contact with it.
Don’t assume that because we
use isolation between different
parts of the circuit that some
parts are safe to touch – they are
not! The isolation between parts
of the circuit is to allow for the
differing voltage potentials in
parts of the circuit rather than for
safety.
Fig.3: in the Soft Starter circuit, the N-channel Mosfet is connected to a diode bridge, so current always flows from its
drain to its source. That way, its parasitic body diode is never forward-biased. The current paths are shown for when the
Active conductor is more positive than the Neutral (i1) and for when the Active is negative with respect to Neutral (i2).
method that is often used.
Leading edge vs trailing edge
Fig.1 shows the mains waveform,
while Fig.2 shows these two types of
power control. Our mains electricity
supply (nominally 230V AC) is a sinewave that repeats 50 times per second
(ie, at 50Hz). For phase control, power
is applied over a portion of each half
of the mains cycle.
The waveforms labelled “A” in Fig.2
show the situation when there is a
small phase angle of the full sinewave
applied to the load. In the left-hand
waveform, the voltage is applied to the
load from late in the waveform until
the zero-crossing. However, on the
right, the voltage is applied for a short
period beginning from 0V, switching
off a little while later.
Both waveforms apply the same
RMS voltage to the load and have the
same area under the shaded portion of
the sinewave curve. The difference is
that one switches on at the end of the
half cycle (leading-edge phase control), while the other switches on at the
beginning of the cycle (trailing-edge
phase control).
Leading edge phase control has been
used for around 50 years, mainly for
dimming incandescent lamps. That is
because it can be implemented using
a simple circuit based on a Triac, a
semiconductor device that switches
on when its gate is driven. It can’t be
switched off via the gate; instead, it
switches itself off when the current
flow through it drops to near zero.
However, leading-edge phase control is unsuitable for providing soft
starting to loads that charge a capacitor. If a voltage is suddenly applied to
that type of circuit, it will create a high
surge current, regardless of whether
the phase angle it is on for is only a
small portion of the mains waveform.
The solution is to use a trailing edge
phase control instead. The switching device now turns on at the mains
zero-crossing where there is little or
no potential difference between Active
and Neutral. The voltage then rises relatively slowly, following the sinewave
shape, to charge the capacitance.
Current is drawn from the mains
in much smaller and more tolerable
pulses. Note that a typical circuit that
charges capacitors includes a rectifier
so that the capacitor is charged with
DC voltage.
For soft starting, we increase the
duration of the waveform applied to
the load over time, so the capacitor
charges in small increments as the
next cycle has a slightly greater phase
length and hence a slightly higher peak
voltage. The capacitor is ultimately
charged, but at a slower rate than if the
full supply were applied at power on.
By the way, trailing edge control
is also used for dimming LED lamps
because they are usually powered by
a capacitor-input switch-mode power
supply (SMPS). If you are interested in
learning more about this, Leo Simpson
wrote about leading and trailing edge
dimmers in July 2017 (siliconchip.au/
Article/10712).
The disadvantage of trailing-edge
phase control is that a Triac cannot be
used. It needs a switching device that
can be switched off at any part of the
mains waveform.
Fig.3 is a simplified version of how
we implement trailing-edge phase control. We use a Metal-oxide Semiconductor Field Effect Transistor (Mosfet) and a rectifier bridge. The Mosfet
is connected within the diode bridge,
so current always flows from its drain
terminal to its source.
The current paths are shown for
when the Active is more positive
than the Neutral (i1) and for when the
Active is negative with respect to Neutral (i2). The Mosfet circuit allows us
to switch mains power to the load on
or off at any point in the mains cycle.
Results
We measured the startup current
for a bank of amplifiers that, when
switched on normally, would trip the
Trailing-edge phase control achieves
a similar result, but instead, the load
is switched on at the zero crossing
and then switched off at some point
later in the mains cycle. The later the
switch-off, the more power is applied
to the load.
siliconchip.com.au
Australia's electronics magazine
February 2023 35
Scope 1: switching on a bank of amplifiers, the current
peaks at 138A until the circuit breaker trips after 6ms.
Scope 2: with the Soft Starter, the bank of amplifiers can
be switched on without tripping the breaker.
Scope 3: the 750W angle grinder draws 40A on the first
mains cycle, dropping to 6A after half a second.
Scope 4: with the Soft Starter, the angle grinder takes four
times longer to spin up and no longer kicks.
circuit breaker. We also tested it with
a 750W angle grinder.
For the amplifiers, the startup load
is essentially a bank of capacitors that
charges up at power-on. When discharged, they effectively form a short
circuit, resulting in a huge current flow
as power is first applied. This is shown
in Scope 1, with each vertical division
corresponding to 50A (10A = 1V here).
The startup surge current (sometimes called the inrush current)
peaks at about 138A before the circuit
breaker trips. The time for the circuit
breaker to trip is less than a mains
half-cycle of 10ms (we measure 6ms
to the small negative spike).
Scope 2 shows the startup current
for the same load with the Active Soft
Starter connected, over a longer period
(the timebase is now 50ms instead of
5ms). The is much more subdued,
with only small peaks to a maximum
of around 17A. The amplifier capacitor
36
Silicon Chip
banks are fully charged after about
500ms, hence the drop-off in the current spikes.
For the 750W angle grinder, the
startup current (Scope 3) peaks at
nearly 40A in the negative direction
and then about 34A in the positive
direction, tapering down to about
6A after 450ms. With the Soft Starter
connected (Scope 4, again with a longer timebase), a small initial current
rises to about 13A peak after 750ms
and tapers to about 5A at the two-second mark.
The fact that it takes considerably
longer to spin up indicates that it has
much less of a ‘kick’ to it.
Block diagram
Block diagram Fig.4 shows how the
circuitry is arranged in the Active Soft
Starter. Incoming mains Active (A)
passes through a fuse and to the mains
output for connection to the appliance
Australia's electronics magazine
while current transformer T1 monitors
the current flow.
The incoming Neutral (N) does not
directly connect to the output, but
instead, goes via the soft-start circuitry
comprising Mosfet Q1 and bridge rectifier BR1. The relay bypasses this
arrangement after the soft-start period.
The Active mains wire passes
through the centre of the current
transformer T1 twice, forming its primary winding. The isolated secondary winding produces a voltage proportional to the Active current. This
is rectified using a precision full-wave
rectifier and low-pass filtered to give
a smoother DC voltage, then fed to
the AN1 analog input of microcontroller IC1.
The current measurement is used for
two purposes. One is to monitor when
the appliance is switched on to initiate soft starting. The other is to determine when the appliance is switched
siliconchip.com.au
Fig.4: a simplified block diagram
of the Active Soft Starter. The
soft-start circuitry is connected
between the incoming and outgoing
Neutral; current flow is monitored
in the Active wire so that it knows
when to activate the soft-starting
procedure. RLY1 bypasses the softstart circuitry once the full voltage
has been applied to the load for
maximum efficiency.
off, to reset the circuitry, ready for the
next power-on.
Microcontroller IC1 controls all the
soft starter functions. It monitors the
appliance current, controls the gate
of Mosfet Q1 and the coil of the relay,
monitors the soft start rate setting
potentiometer and also monitors the
mains waveform zero-crossing timing.
The gate drive for the Mosfet needs
to be referenced to the negative terminal of the bridge rectifier, which is neither at Neutral nor Active potential. So
For IC1 to drive the Mosfet, there needs
to be electrical isolation between IC1
and Q1’s gate. This is achieved using
an isolated power supply and an isolated gate driver.
The isolated supply is produced via
the GP4 digital output of IC1 that delivers a 1MHz, 5.5V square wave. That
waveform is stepped up and isolated
via transformer T2. After rectification
and filtering, the result is a DC voltage suitable for driving the gate of Q1.
The Mosfet gate is controlled via
the GP0 digital output of IC1. This
drives an opto-coupler (IC3) containing an infrared LED that is electrically isolated from the opto-coupler’s
siliconchip.com.au
optically switched transistor. That
transistor controls the voltage at the
gate of Mosfet Q1.
The isolated drive for the relay coil
is via an optically-coupled Triac driver
(IC4) that connects the lower end of the
coil to the output Neutral. The relay
has a 230V AC coil with the top end
connected to Active and the bottom
end connecting to IC4.
IC4 has an internal LED that optically triggers the output Triac. It is typically used to drive the gate of a larger
Triac, but for our circuit, we are just
using it to power the relay coil.
The power supply for IC1 is not
shown in Fig.4; its supply is derived
via a mains-rated capacitor that acts
as a current limiter to a zener diode
clamp, resulting in the 5.5V supply
voltage. The positive side of this supply is referenced to mains Active.
Potentiometer VR1 is used for the
soft start rate adjustment. It is connected across that 5.5V supply, producing a varying voltage at the microcontroller’s AN2 analog input.
Neon indicators
NEON1 lights when there is mains
Australia's electronics magazine
power at the input. NEON2 is connected across the mains output, so it
starts dim and reaches full brightness
when the soft start period ends. We
call this the “run” indicator. Finally,
NEON3 lights when the relay is on
after the soft start period completes.
This is called the soft start “end”
indicator.
Circuit details
The entire circuit is shown in Fig.5.
A lot of the circuitry has already been
explained by the block diagram. However, several parts of the circuit haven’t
been described in any detail.
As mentioned earlier, Triac-output
opto-coupler IC4 drives the relay coil.
We are using the MOC3042 with zero
voltage crossing detection, so its Triac
always switches on when the mains
supply is at zero voltage. That is not
strictly necessary for our circuit, but
it does not hurt. Its internal Triac
between pins 4 and 6 is guaranteed
to trigger, provided there is at least
10mA through the internal infrared
LED between pins 1 and 2.
We also include a snubber across
the Triac terminals, comprising a 22nF
February 2023 37
Fig.5: IC1 is the controlling PIC while generating an isolated Mosfet gate voltage supply by feeding a high-frequency
square wave into transformer T2. It controls the Mosfet gate across that isolation barrier using opto-coupler IC3, and
it monitors the output of the current sense transformer via the full-wave precision rectifier formed by dual op amp
IC2. Two transient voltage suppressors and a zener diode protect Mosfet Q1 from voltage spikes.
X2-rated mains capacitor and a 150W
resistor, connected in series between
its pins 4 and 6. This limits the voltage rise time so that the Triac will not
switch itself on when power is first
applied to the circuit.
The 1MW resistor just discharges the
capacitor when power is off for safety.
The snubber limits sudden voltage rises across the Triac by charging
38
Silicon Chip
over time via the 150W resistor. This
prevents the voltage from rising faster
than 1000V/μs, which is the maximum
dV/dt rating for the Triac in IC4, below
which it is guaranteed not to switch
on by itself.
Another precaution against that
is connecting pin 4 of the Triac to
the Neutral output of the soft-start
circuitry rather than directly to the
Australia's electronics magazine
incoming Neutral. So when power is
first applied, there is no voltage across
the Triac. As the soft start process
begins, the voltage across it rises at a
controlled rate.
Protecting Mosfet Q1
As well as a snubber for IC4, there
is a 220nF/470W snubber across the
AC terminals of BR1 to reduce the
siliconchip.com.au
magnitude of voltage spikes seen
by Mosfet Q1. This also has a 1MW
bleeder resistor for safety. This snubber also provides a small current flow
when an appliance is switched on
before the soft starting process has activated. This is enough current to detect
and initiate the soft start.
Q1 is also protected against over-
voltage conditions that could destroy
the device; it has a 500V maximum
drain-source rating. Two transient
voltage suppressors (TVS) are used
to prevent the voltage from going over
that limit.
TVS2 is connected directly between
the Mosfet’s drain and source and
conducts to shunt voltage at the TVS
clamp voltage of 400V (255V AC rectified gives ~360V DC). However,
this TVS can be damaged if the over-
voltage spike has too much energy, so
a second line of defence is used.
A second TVS, TVS3, is connected
in series with a 100W resistor between
the Mosfet drain and gate. If the drain
voltage rises too high, TVS3 conducts
and causes the Mosfet gate voltage to
rise, so the Mosfet starts to conduct,
shunting the voltage spike itself.
Zener diode ZD3 prevents the gate
voltage from going over 15V in this
case, which could otherwise damage
it, while the 100W resistor limits the
zener current to a safe level.
Current detection
Current transformer T1 produces
an output current from its secondary
winding that’s proportional to the current flow through the Active mains
wire. The 10kW loading resistor gives
about 4V AC output with a current flow
of 1A and one turn of the Active mains
wire through the current transformer
core. We use two turns through the
core, giving about 4V AC with 500mA
current through the primary.
While the input current to output
voltage conversion is not very linear
using a 10kW loading resistance, we
use the high value to improve sensitivity. A 100W loading resistor would
be used instead for this current transformer to measure current accurately.
That would provide a more linear relationship but only gives 1V AC for a
10A primary current.
Current sense
voltage rectification
Another transient voltage suppressor (TVS1) clamps the output voltage
siliconchip.com.au
from transformer T1. This limits the
current into the following op amp
inputs to a safe level.
The output from T1 needs to be rectified to give a DC voltage suitable for
monitoring by microcontroller IC1. A
precision full-wave rectifier is used,
made from dual op amp IC2 and associated resistors; note the lack of diodes.
The gain of this precision rectifier is 1.5 times. While it may appear
impossible to rectify the incoming AC
voltage without diodes, it is possible,
provided that the op amp has specific
characteristics.
The op amp needs to be able to
operate with an input below its negative supply rail, and the op amp must
be able to pull its output close to that
negative supply rail.
Here, we are using an MCP6272
dual op amp (IC2). One stage (IC2b)
is connected as a unity gain buffer,
while the other (IC2a) provides the
1.5 times gain.
To understand how the rectification
works, refer to Fig.6, where A to E correspond to the waveforms at the identically labelled parts of the circuit in
Fig.5. That is assuming that our example waveform is present at point A.
Sample waveform A is a 2V peak-topeak sinewave. For the negative half
of the cycle, the signal applied to the
non-inverting pin 5 input of IC2b via
the 15kW resistor will cause the voltage at that pin (point B) to be clamped
at around -0.3V due to IC2’s internal
input protection diode.
The output of IC2b (point C) therefore sits at 0V during negative portions
of the cycle, since its negative supply
rail is at 0V, and it cannot pull its output lower than that.
IC2a adjusts its output (point E) so
that the voltage at its inverting input
pin 2 (point D) matches the voltage at
non-inverting input pin 3 (point C).
Since the 10kW resistor from point D
to ground has no voltage across it, it
plays no part in the circuit during the
negative portions of the cycle.
With the 10kW resistor essentially
out of the circuit, IC2a operates as
a standard inverting amplifier with
both inputs (points C and D) at 0V.
Its gain is therefore -30kW divided
by 20kW, which equals -1.5 times.
So the -1V peak of the waveform is
amplified and inverted to produce
+1.5V at point E.
The way it works for a positive
voltage at the input (point A) is more
Australia's electronics magazine
complicated. Firstly, the voltage at pin
5 (point B) is reduced compared to the
1V peak at the input. This is because
of the divider formed by the 15kW and
18kW resistors, so the voltage becomes
0.5454V (1V × 15kW ÷ [15kW + 18kW]).
Point C will also peak at 0.5454V
since IC2b is working as a unity-gain
buffer producing the same voltage at
its output as its non-inverting input.
Once again, op amp IC2a adjusts the
output voltage (point E) so that the
voltage at the inverting input at pin
2 (point D) matches the voltage at the
non-inverting input, pin 3 (point C).
To determine the resulting voltage,
we must calculate the currents through
the three resistors connecting to the
inverting input of IC2a at point D.
1. The current through the 10kW
resistor is the waveform D voltage divided by 10kW. This peaks at
54.54μA (0.5454V ÷ 10kW).
2. The current through the 20kW
resistor; with 1V peak at the input
(point A), there will be 22.73μA ([1V[A]
− 0.54V[D]] ÷ 20kW).
So we have 22.73μA flowing into the
node at point D via the 20kW resistor
and 54.54μA flowing away from that
node via the 10kW resistor. The extra
Fig.6: these waveforms demonstrate
how the active precision rectifier used
for current monitoring works. They
correspond to the expected waveforms
at the points marked A-E on the
circuit for the condition where there
is a 2V peak-to-peak sinewave at
point A, corresponding to a resistive
load drawing about 88mA RMS.
February 2023 39
input (GP3) is filtered with a 4.7nF
capacitor, providing a near-zero voltage when the mains voltage is at zero.
IC1’s pin 4 input detects when this
voltage changes from being positive to
zero or negative and vice versa.
The voltage at pin 4 is clamped by
the internal protection diode to -0.3V
during the negative part of the cycle.
For positive excursions of the mains
waveform, diode D2 clamps the voltage to about 0.6V above the 5.5V
supply or close to 6V. This diode is
required since the pin 4 input is not
protected with a diode to the positive
supply. That’s so this input can be used
for programming the microcontroller,
where the voltage at this pin needs to
go above the supply voltage.
A sneak peek at
the assembled PCB for
the Active Mains Soft Starter, with
construction details coming next month.
current to balance currents at node D
needs to come via the 30kW resistor.
This is 31.81μA (54.54μA − 22.73μA).
Remembering that voltage at point D
peaks at 0.54V, the required voltage
at point E is 1.5V (31.81μA × 30kW
+ 0.54V).
So the circuit operates as a full-wave
rectifier with a gain of 1.5. The degree
of precision depends on the op amp
parameters and resistor tolerances.
The lower the offset voltage of the op
amp and the lower the op amp input
bias current, the more accurate the fullwave rectification will be, particularly
at low signal levels.
Fortunately, we are not overly concerned with absolute accuracy here.
We just need full-wave rectification
of the incoming AC signal from the
current transformer.
Scope 5 shows the 1V peak sinewave at the input to the full wave rectifier (point A) on channel 1, shown
in yellow. Below that is the full-wave
rectified waveform at point E, shown
in cyan.
A 2.2kW resistor and 10μF capacitor filter the rectified waveform to produce a smoothed DC voltage suitable
for the IC1 to monitor via its AN1 analog input and internal analog-to-digital
converter (ADC).
Mains zero-crossing detection
IC1 monitors the mains waveform
at the mains Neutral via a 330kW 1W
resistor. The voltage at its pin 4 digital
Scope 5: the input to the active rectifier at point A and the
output below (point E). Note the gain.
40
Silicon Chip
Mosfet gate drive
To drive the Mosfet gate, we need
an isolated DC supply and a method
of connecting and disconnecting that
supply to the gate. As mentioned previously, these voltages need to be galvanically isolated from IC1.
The isolated DC supply is generated by applying a 1MHz square
wave to the primary winding of high-
frequency transformer T2 from IC1’s
clock output at GP4 (pin 3). This is
¼ the frequency of its internal 4MHz
oscillator. The primary has 10 turns,
while the secondary has 48, giving a
4.8:1 voltage ratio.
Since the primary is a 5.5V peak-topeak square wave, we can expect the
secondary to deliver a 26.4V (5.5V ×
4.8) peak-to-peak square wave. After
half-wave rectification by diode D3,
we obtain a 13.2V DC output that is
filtered by a 1μF capacitor. 15V zener
Scope 6: the isolated Mosftet gate drive signal. It switches
on faster than it switches off due to the isolation scheme.
Australia's electronics magazine
siliconchip.com.au
diode ZD2 limits the voltage to a safe
level for the Mosfet gate.
The Opto-coupled output transistor of IC3 switches the Mosfet gate on
or off. It is driven by the pin 7 digital output (GP0) of IC1. When this is
high (at 5.5V), it drives the internal
infrared LED of IC3 via a 1.5kW current-limiting resistor. The LED then
lights and switches on the output
transistor within IC3 that connects the
13.2V DC supply to the gate of Q1 via
a 47W resistor.
When the GP0 output of IC1 goes
low (to 0V), IC3’s LED switches off,
so the gate of Q1 is pulled to 0V by
the 22kW resistor, switching the Mosfet off.
Scope 6 shows the gate drive to the
Mosfet when driven for 5ms on and
5ms off at 100Hz. When switched
on, the gate voltage is initially 14.3V,
drooping to 12.3V over the 5ms period.
The voltage droop is due to the 1μF
capacitor being loaded by the 22kW
gate-source resistor.
The switch-on rise time is around
43μs and the fall time is 324μs. The
fall time is longer due to the 22kW discharge resistor having a higher resistance than the opto-coupler output
transistor and 47W resistor that charges
the gate up.
Power supply
Power for microcontroller IC1 and
op amp IC2 is derived directly from
the mains using a 470nF X2 mainsrated safety capacitor. The circuit
operates by transferring charge to a
470μF capacitor via zener diode ZD1
and diode D1.
For one polarity of the mains waveform, D1 is reverse-biased and ZD1 is
forward-biased, so the charge from the
470nF capacitor is transferred to the
470μF supply filter capacitor. During
the other half of the mains waveform,
diode D1 is forward-biased and the
zener diode clamps to 6.2V between
the +5.5V supply rail and the cathode
(K) of D1.
Since the forward voltage of diode
D1 is about 0.7V, the overall voltage
across the 470μF capacitor is limited
to 5.5V (6.2V − 0.7V).
Next month
The follow-up article next month
will have all the construction details
for the Active Mains Soft Starter, along
with the testing procedure and usage
instructions.
SC
siliconchip.com.au
Parts List – Active Soft Starter
1 double-sided, plated-through PCB coded 10110221, 159 × 109mm ●
1 171 × 121 × 55mm polycarbonate or ABS enclosure [Altronics H0478, Jaycar HB6218]
1 153 × 107mm panel label
1 10A IEC panel-mount mains input socket with integral fuse holder
[Altronics P8324, Jaycar PP4004]
1 10A IEC mains power lead
1 mains GPO socket [Altronics P8241, Jaycar PS4094]
1 Talema AX1000 or AC1010 10A current transformer (T1) ●
1 Hongfa HF105F-4/240A1HSTF 30A 240VAC chassis mount relay, 240V AC coil (RLY1) ●
1 SL32 10015 15A 265V AC NTC thermistor (NTC1) ●
3 plastic-bodied mains neon indicators (NEON1-NEON3; optional)
[Altronics S4016, Jaycar SL2630]
1 10A M205 fast-blow fuse (F1)
4 2-way 15A 300V screw barrier terminals (CON1-CON4) [Altronics P2101]
1 100kW linear PCB-mount potentiometer (VR1) [Altronics R1948]
1 8-pin DIL IC socket (for IC1)
1 18 × 10 × 6mm ferrite toroid (for T2) [Jaycar LO1230]
Hardware & wire
1 1.25m length of 0.25mm diameter enamelled copper winding wire (for T2)
2 4.8mm insulated female spade crimp lugs
1 350mm length of (blue & brown) 7.5A mains-rated wire
1 200mm length of blue 10A mains-rated wire
1 250mm length of brown 10A mains-rated wire
1 150mm length of green/yellow striped 10A mains-rated wire
1 75mm length of 10mm diameter heatshrink tubing
1 20mm length of 5mm diameter (blue, red & green) heatshrink tubing
1 20mm length of 3mm diameter (blue & red) heatshrink tubing
1 20 × 15mm piece of thermal transfer tape [Altronics H7240, Jaycar NM2790]
2 M3 × 10mm Nylon countersunk machine screws
2 M3 × 15mm panhead machine screws
4 M3 × 6mm panhead machine screws
4 M3 hex nuts
17 100mm cable ties
black tubing can be used instead, if preferred.
Semiconductors
1 PIC12F617-I/P 8-bit microcontroller programmed with 1011022A.hex, DIP-8 (IC1) ●
1 MCP6272T-E/SN dual rail-to-rail op amp, SOIC-8 (IC2) ●
1 4N28 or 4N25 opto-coupler, DIP-6 (IC3) ●
1 MOC3042M or MOC3043M zero-crossing triggered Triac driver, DIP-6 (IC4) ●
1 SIHS36N50D-GE3 36A 500V N-channel Mosfet, TO-247 (Q1) ●
1 PB5006 45A 600V bridge rectifier (BR1) ●
1 6.2V 1W zener diode (ZD1) [1N4735] ●
2 15V 1W zener diodes (ZD2, ZD3) [1N4742] ●
1 4KE15CA bidirectional TVS, 400W, 12.8V standoff (TVS1) [Jaycar ZR1160] ●
1 1.5KE400CA bidirectional TVS, 1500W, 342V standoff (TVS2) [Jaycar ZR1180] ●
1 4KE400CA bidirectional TVS, 400W, 342V standoff (TVS3) [Jaycar ZR1164] ●
1 1N4004 400V 1A diode (D1) ●
2 1N4148 75V 200mA diodes (D2, D3) ●
Capacitors
1 470μF 16V PC electrolytic
1 220nF X2-rated metallised polypropylene (PP)
2 10μF 16V PC electrolytic
4 100nF 63V or 100V MKT polyester
1 1μF 50V multi-layer ceramic
1 22nF X2-rated metallised polypropylene (PP)
1 470nF X2-rated metallised PP
1 4.7nF 63V or 100V MKT polyester
Resistors (all 1/2W metal film ±1% unless noted)
3 1MW 1W ±5%
1 15kW
1 330W
1 330kW 1W ±5%
2 10kW
1 150W 1W ±5%
1 30kW
1 2.2kW
1 100W
1 22kW
1 1.5kW
2 47W
1 20kW
1 1kW 5W ±5% wirewound
1 18kW
1 470W 1W ±5%
● these parts are available as part of a set from the Silicon Chip Online Shop, Cat SC6575,
for $100 + P&P. All the other parts are available from Jaycar or Altronics.
Australia's electronics magazine
February 2023 41
|